Rocket motor

A model rocket motor turns stored chemical energy into thrust by sending hot gas backwards through a nozzle.

How a motor makes thrust

A rocket motor stores chemical potential energy in its The material in a commercial motor that produces gas as it burns.. Burning the propellant turns some of this energy into kinetic energy and produces hot gas inside the casing. The gas expands through the The opening that directs gas out of the motor. and rushes out of the back of the rocket.

The exhaust carries momentum backwards, so by conservation of momentum the rocket gains momentum forwards. This gives the rocket The forward pushing force produced as a motor expels gas backwards.. In a model motor the propellant is solid. The manufacturer forms it to fit the casing, which makes it straightforward to store and handle as directed.

Cutaway of a composite rocket motor showing the nozzle, propellant, delay grain and ejection charge.
Composite motor cutaway from Estes Education.View larger image

Black powder motors use pressed propellant and are common in smaller models. Composite motors use a solid A factory-formed piece of solid propellant. Its shape helps set how the motor burns. and can pack more energy into a given mass. Both cutaways show the propellant behind a nozzle, with the recovery components at the other end.

In a motor with ejection recovery, the The part of some commercial motors that continues burning after thrust ends, before recovery ejection. provides time for the rocket to coast after the main burn. It often gives off A streak of smoke that makes the rocket easier to follow in the sky. during the coast. When the delay is over, the A built-in section of some commercial motors that produces gas to release recovery equipment. releases the recovery system. Motors designed for other jobs can omit these parts.

Estes black powder motor cutaway with pressed propellant, a clay nozzle, delay and ejection charge.
Black powder motor cutaway from Estes.View larger image

Thrust curve and sequence

A A graph showing how a motor’s thrust changes with time. shows the motor’s push as it changes with time. The area under the powered part is its The motor’s total pushing effect over its powered burn, measured in newton-seconds (N s)., measured in newton-seconds (N·s). You can also calculate it as average thrust × burn time. Two motors can deliver the same impulse as a short, strong push or a longer, gentler one.

Illustrative thrust curve. Use measured data for your chosen motor. View full illustration ↗

Ignition

The launch controller heats the igniter tip. It lights a small part of the propellant, then the burn spreads quickly. Thrust rises sharply at the start of the curve.

Powered thrust

The main propellant burns and sends hot gas through the nozzle. The example has a lower, fairly steady push after its first peak. The shape varies by motor. The main burn ends at burnout.

Coasting and tracking smoke

After burnout, the rocket keeps moving upwards while gravity and drag slow it. The delay grain continues to burn and often gives off A streak of smoke that makes the rocket easier to follow in the sky.. The delay on the label is timed from burnout.

Ejection

At the end of the delay, the ejection charge makes a short burst of gas. The pressure opens the intended joint and releases the recovery system. The small bump on the curve marks that event.

Motor codes and impulse

The letter in a motor code tells you its total impulse class. Class A goes up to 2.5 N·s. Starting with B, both ends of the range double each time you move up a class. B covers over 2.5 to 5 N·s. Doubling both limits gives C, over 5 to 10 N·s.

A code like F20-6 would mean F class (over 40 to 80 N·s), 20 N nominal average thrust and 6 seconds from burnout to ejection. The peak thrust is a separate value. It is the highest point on the measured curve and helps you check the load the motor mount must carry.

You may see a maker code before the designation, such as AT for AeroTech. Use the maker and full designation to find the right motor data. For a rocket with more than one motor, add the measured impulses. Three Estes D12-5 motors at about 16.84 N·s each give 50.52 N·s together, which falls in F class.

ClassTotal impulse (N·s)UKRA certification
AUp to 2.5—
BOver 2.5 to 5—
COver 5 to 10—
DOver 10 to 20—
EOver 20 to 40—
FOver 40 to 80—
GOver 80 to 160—
HOver 160 to 320Level 1

At UKRA club launches, H and above require the relevant high power certification. The rating is based on the combined impulse. The event rules may set a lower limit.

Ignition

An igniter starts the motor by lighting its propellant. The launch controller sends current through a thin wire at the igniter tip, heating it. On some igniters the hot wire lights a A heat-producing material on the tip of some electric igniters that helps light the main propellant. coating, which then ignites the propellant. If the bare leads or clips touch, they can short the circuit and divert current away from the tip, causing a misfire.

An igniter diagram labelling the pyrogen-coated wire, card and two terminals.
Parts of a pyrogen-coated igniter. Source: Estes Education.View larger image

For an Estes black powder motor, the starter tip needs to touch the propellant. Handle the fragile tip gently and use the supplied plug to keep it in contact.

Two cutaways compare a starter tip that touches the propellant with one that leaves a gap.
The plug holds the starter tip against the propellant. Source: Estes Education.View larger image

The fitting diagram shows the starter, plug and clips for an Estes motor. Follow the Estes starter guide for that type of motor.

For a composite motor, follow the instructions that came with it. Some designs place the igniter well inside the propellant core. Seat and secure it as the manufacturer specifies. If the motor misfires, stay back and follow the Range Safety Officer: the person responsible for safety in the launch area and for approving a launch.’s instructions. See safe launch.

Estes diagram showing the steps for fitting a black powder motor starter, retaining plug and clips.
Starter fitting for an Estes black powder motor. Source: Estes Education.View larger image

Single use and reloads

A single-use motor comes as a complete unit. It goes into the matching motor mount and you replace the whole motor after the flight. It is usually the simpler choice when you are getting started.

A reloadable motor has a reusable metal casing and a specified reload kit. The kit supplies the factory-made grains, nozzle and other consumable parts. You replace the used parts and keep the casing for compatible reloads. You can use the case in another rocket if its mount and flight design suit the motor.

The casing costs more up front, but repeated flights can bring the cost per flight down. Reloads take more care to assemble and check. Some systems offer several delays or approved adjustments. Use the delay options and method specified for that motor.

An AeroTech D13-10W reload kit with propellant grains, nozzles, seals and other parts.
An AeroTech D13-10W reload kit for a matching reusable casing.View larger image

Fitting and launch checks

Choose a permitted commercial motor with your supervisor. Check that the motor mount fits its casing, can carry the motor’s thrust and retains it during ejection. The nozzle faces out of the rear of the rocket. Follow the launch day instructions from the Range Safety Officer: the person responsible for safety in the launch area and for approving a launch..

Deployment problems

An early or late ejection can pull the shock cord tight while the rocket is moving fast, tearing the canopy or cutting into the body tube. A late ejection also leaves less height for the rocket to slow down. Use your simulation to check how fast the rocket is moving at deployment and aim to open the recovery system near apogee.

Choosing a motor

Compare the exact motor’s dimensions, mass, measured thrust curve and available delays. If you choose a reload, check which casing and closures it needs. Rockets and Things is one UK supplier.

For UKROC, choose from the competition’s current approved motor list and check the event rules for combined impulse. UKROC 2027 approved motor list.

Two AeroTech F20-7W single-use model rocket motors and an igniter.
The photographed AeroTech F20-7W has a nominal seven-second delay.View larger image

OpenRocket

Mark the inner tube as a motor mount, then select the actual motor in Motors & Configuration. The original demonstration uses AeroTech F20W/L. The tube dimensions in slide 18 are examples. Check the tube’s inside diameter against the motor casing you intend to use.

Use Show Details to see the thrust curve, dimensions, mass and available delays. Select an available delay and simulate the flight. Check the speed off the rail, stability and deployment timing. OpenRocket flight simulation guide.

Original slide comparing two cutaways of commercial model rocket motors.
Slide 13 · Motor anatomyView larger

Black powder and composite motor cutaways identify the casing, nozzle, propellant, delay and ejection charge.

Original slide explaining the ignition, thrust, coast and ejection stages.
Slide 14 · How motors workView larger

The electric igniter starts the propellant. The motor produces thrust until burnout. A delay may give off tracking smoke while the rocket coasts, before the ejection charge deploys recovery.

Original slide with the illustrative thrust curve and drawings of the four motor stages.
Slide 15 · Thrust curvesView larger

The curve rises sharply at ignition, shows thrust during the burn and falls at burnout. Coasting continues through the delay until ejection.

Original slide showing F20-4, the impulse class system and combined impulse.
Slide 16 · Total impulse classesView larger

The letter tells the total impulse range. The upper limit doubles with each class. A rocket with more than one motor uses their combined total impulse.

Original slide identifying total impulse class, average thrust and delay in F20-4.
Slide 17 · Reading a motor codeView larger

Total impulse is average thrust multiplied by burn duration. In the F20-4 example, the F gives the class, 20 gives nominal average thrust and 4 gives the delay after burnout.

Original OpenRocket screenshots showing an inner tube and the Motor tab checkbox.
Slide 18 · Creating a motor mountView larger

Select the body tube, add an Inner Tube and open its Motor tab. Select This component is a motor mount. The dimensions shown are for the demonstration.

Original OpenRocket screenshots showing Motors and Configuration and a search for F20.
Slide 19 · Selecting a motorView larger

In Motors & Configuration, select the intended motor mount and choose a motor for that configuration. The example searches for AeroTech F20W/L.

Original OpenRocket slide showing the Show Details panel and the F20 thrust curve.
Slide 20 · Motor detailsView larger

Show Details displays data for the selected motor, including its dimensions, impulse, thrust curve and delay options. Use the exact motor and delay in the simulation.

Sources & further reading

Scroll to Top